Shaft runout, vibration and thermal monitoring of hydro units
The TURBO-M system, a registered measuring instrument, on 50+ hydro units of TGC-1 cascades.
| Years | 2010–2017 |
|---|---|
| Client | TGC-1 PJSC: Karelia, Kola and Neva branches |
| Location | Karelia, Murmansk and Leningrad regions, Russia |
| Role | Chief project engineer, then CTO of NPO Systema |

Challenge
Continuously monitor shaft runout and bearing temperatures and send warning and trip signals to hydro-unit protection.
Solution
The TURBO-M system (type approval RU.C.34.001.A No. 52040) with sealed runout sensors (RU.C.27.004.A No. 52938); 1 MHz ADC with error under 0.025%; touch panel, operator workstation, data to the plant control system and over GPRS; dual independent power supply.
My part
Technical solutions and proposals, project management, metrological certification, approvals with the client.
Outcome
Over 50 hydro units on the Vyg, Kem, Niva, Paz, Suna, Serebryanka, Tuloma and Ladoga cascades, including Belomorskaya and Vygostrovskaya (2016), Nizhne-Svirskaya (2016), Hyamekoski and Harlu (2014), Poduzhemskaya (2013).