Shaft runout, vibration and thermal monitoring of hydro units

The TURBO-M system, a registered measuring instrument, on 50+ hydro units of TGC-1 cascades.

HydroVibrationMetrologySCADA
Years2010–2017
ClientTGC-1 PJSC: Karelia, Kola and Neva branches
LocationKarelia, Murmansk and Leningrad regions, Russia
RoleChief project engineer, then CTO of NPO Systema
Shaft runout by bearing
Shaft runout by bearing

Challenge

Continuously monitor shaft runout and bearing temperatures and send warning and trip signals to hydro-unit protection.

Solution

The TURBO-M system (type approval RU.C.34.001.A No. 52040) with sealed runout sensors (RU.C.27.004.A No. 52938); 1 MHz ADC with error under 0.025%; touch panel, operator workstation, data to the plant control system and over GPRS; dual independent power supply.

My part

Technical solutions and proposals, project management, metrological certification, approvals with the client.

Outcome

Over 50 hydro units on the Vyg, Kem, Niva, Paz, Suna, Serebryanka, Tuloma and Ladoga cascades, including Belomorskaya and Vygostrovskaya (2016), Nizhne-Svirskaya (2016), Hyamekoski and Harlu (2014), Poduzhemskaya (2013).